Gaggenau 400 series Vario gas cooktop 90 cm Liquidgas G30,31 28-30/37 mbar VG491115F

400 SERIES VARIO GAS COOKTOP 90 CM LIQUIDGAS G30,31 28-30/37 MBAR VG491115F

Gaggenau 400 series Vario gas cooktop 90 cm Liquidgas G30,31 28-30/37 mbar VG491115F

400 SERIES VARIO GAS COOKTOP 90 CM LIQUIDGAS G30,31 28-30/37 MBAR 

VG491115F

information

COOKING ZONES 

-1 multi-ring wok burner (300 W – 5800 W), suitable for pots up to max. ø 32 cm. -2 two-ring high output burners (165 W – 4000 W), suitable for pots up to max. ø 28 cm. -2 two-ring standard burners (165 W – 2000 W), suitable for pots up to max. ø 24 cm.

BRAND 

Gaggenau

PRODUCT TYPE

Gas Cooktop

APPLIANCES 

Can be combined perfectly with other Vario appliances of the 400 series

COLLECTION

400 Series

PRODUCTION

Made in Africa

Gaggenau 400 series Vario gas cooktop 90 cm Liquidgas G30,31 28-30/37 mbar VG491115F

BASIC SURFACE MATERIAL 

Brushed Stainless Steel

MAIN COLOUR OF PRODUCT 

Stainless Steel

SAFETY

-Safety Shut-off. -Residual Heat Indication -Electronic Flame Monitoring With Automatic Re-ignition.

SAFETY FUNCTIONS

- Safety Valve
- Automatic Reignition
- Electronic Flame Control

Gaggenau 400 series Vario gas cooktop 90 cm Liquidgas G30,31 28-30/37 mbar VG491115F

HANDLING

-Control knobs with illuminated ring, cooking zone and output level markings. -One-handed operation. -Full electronic control in 12 output levels for exact power level regulation plus simmer function. -Automatic fast ignition.

FULL ELECTRONIC POWER LEVEL REGULATION ON 12 LEVELS 

The illuminated controls offer 12 levels of electronically controled heat, ensuring the flames are consistent

CAN BE COMBINED PERFECTLY WITH OTHER VARIO APPLIANCES OF THE 400 SERIES 

Can be combined perfectly with other Vario appliances of the 400 series

BURNERS AND POWER

- Total number of positions that can be used at the same time : 5
- Type Cooking zone : High-speed burner, Standard burner, WOK burner

KOMFORT 

- 9 precise power levels : Yes 
- Location of control panel : External
- Dishwasher suitable pan support : No

RESIDUAL HEAT INDICATOR 

Yes

MAIN ON/OFF SWITCH 

No

FEATURES

-Simmer Function. -Brass Burner Rings. -Three-part cast iron pan support with flat, continuous pot surface.

CONNECTION

-Total connected load electric 15 W.
- Connecting cable 1.4 m with plug.
- Total connected load gas 17.8 KW.

Gaggenau 400 series Vario gas cooktop 90 cm Liquidgas G30,31 28-30/37 mbar VG491115F

INSTALLATION

- Connection : With Plug
- Type of appliance width : 90 cm
- Length of connection cable : 140.0 cm
- Minimum worktop thickness : 30 mm
- Gas Type : Liquidgas G30,31 28-30/37 mbar
- Alternative gas type : Nat gas L/LL G25/20mbar(DE)

MATERIAL OF PAN SUPPORTS 

Cast Iron With Rubber Feet

POWER LEVEL 

Full electronic power level regulation on 12 levels

PLANNING NOTES

-Depending on the type of installation (surface-mounted or flush-mounted, with or without an appliance cover), the specific location of the cut-out and the knob positions may vary. -The horizontal positioning of the knobs may be aligned with the specific burners. -The drawing "Installation of the control knob" must be observed if the panel is more than 23 mm thick (there must be a recess at the rear). -If combining several Vario appliances of the 400 series, a connection strip VA 420 must be placed between the appliances. Depending on the type of installation, the corresponding connection strip must be provided. -The bearing capacity and stability, in the case of thinner worktops in particular, must be supported using suitable substructures. Take into account the appliance weight and additional loads.

ADDITIONAL INSTRUCTIONS FOR FLUSH MOUNTING

-Installation is possible in worktops made of stone, synthetics or solid wood. Heat resistance and watertight sealing of the cut edges must be observed. Concerning other materials please consult the worktop manufacturer. -The groove must be continuous and even, so that uniform placing of the appliance on the gasket is ensured. Do not use discontinuous lining. -The joint width may vary due to size tolerances of the combinations and of the worktop cut-out. -If installing several appliances in individual cut-outs allow for a division bar of minimum 50 mm between the individual cut-outs. -Special nozzles can be ordered as spare parts. -Plan for an electrical connection (the appliance is not operable without power supply). -Air intake from above. -No intermediate shelf required. -Rear panel and wall trims must be heat-resistant and consist of a non-flammable material.

-A minimum clearance of at least 150 mm from adjacent heat-sensitive furniture or contact surfaces must be observed or thermal insulation fitted. -If operated next to the downdraft ventilation VL 414, the ventilation moulding AA 414 is recommended to ensure maximum performance of the cooktop. -With a total connected load of more than 11 kW local regulations concerning room ventilation, room size and combination of extraction or recirculation hoods must be observed. -The minimum distance between the cooktop surface and a cabinet above, out of combustible material, needs to be 70 cm. -The minimum distance to a ventilation above is shown at the planning hints for the individual ventilation product. -Appliance can be snapped into the worktop from above. -Appliance weight: approx. 13 kg.